D5014D

SIL 3 Repeater Power Supply Hart

Description

The dual channel Repeater Power Supply, D5014D module, is a high integrity analog input interface suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed.2) in safety related systems for high risk industries.
Provides a fully floating dc supply for energizing conventional 2/3 wires 0/4-20 mA, active or passive, transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional communication signals, for Hart transmitters.
Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area / Non Hazardous Location or in Zone 2 / Class I, Division 2 or Class I, Zone 2.

Features

• Systematic capability SIL 3
• 2 fully independent channels.
• Input from Zone 0 (Zone 20) / Division 1, installation in Zone 2 / Division 2
• 0/4-20 mA Input / Output Signal Active-Passive / Source-Sink
• Hart compatible.
• Input and Output short circuit proof.
• High Accuracy.
• Three port isolation, Input/Output/Supply.
• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system.
• In-field programmability by DIP Switch.
• Type Approval Certificate DNV for marine applications.
• High Density, two channels per unit.
• Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards.
• 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.

Supply

24 Vdc nom (18 to 30 Vdc)

Channels

2 (1 Channel: D5014S)

SIL level

SIL 3
D5014D - SIL 3 Repeater power supply hart compatible

request a quotation

Download

    DTS0280 D5014D data sheet (English) (PDF 472 KB)
    ISM0103D5014D instruction manual (PDF 928 KB)
    ISM0121D5000-D5200 Series General Instruction Manual (PDF 3.27 MB)
    ISM0159FM Control Drawing for D5014S, D5014D (PDF 139 KB)
    ISM0156D5000 Series Safety Instruction Manual (PDF 5.24 MB)
    ISM0273UL Control Drawing for D5014S, D5014D (PDF 90 KB)
    CRT005UL & C-UL barriers listing [link E222308] (PDF 227 KB)
    CRT058ATEX certificate n. BVS 10 ATEX E 113 X (PDF 4.61 MB)
    CRT062IECEx CoC for D5000 Series [link IECEx BVS 10.0072X] (PDF 8.31 MB)
    CRT084Metrological Certificate for D5000 Series (Russia) (PDF 2.13 MB)
    CRT110FM 3046304 (USA) & FM-C 3046304C (Canada) for D5000 Series (PDF 314 KB)
    CRT126DNV Maritime Type Approval Certificate (D5000 Series) (PDF 1.68 MB)
    CRT127INMETRO Certificate DNV 13.0109 X (PDF 619 KB)
    CRT128TÜV SIL Certificate Summary (PDF 1.97 MB)
    CRT130TÜV SIL Functional Safety Certificate (PDF 65 KB)
    CRT136TRCU Certificate for D5000 Series (PDF 1.35 MB)
    CRT153Korean Register Type Approval Certificate (PDF 1.22 MB)
    CRT169NEPSI cert. no. GYJ14.1406X (PDF 6.93 MB)
    CRT183TIIS Certificate for D5014 (PDF 1.84 MB)
    CRT218Ukraine certificate for D5000 series (PDF 2.80 MB)
    CRT253Metrological Certificate for D5000/D6000 Series (Belarus) (PDF 1.80 MB)
    JDFT04912mm DIN Rail Connector
    MCHP196Power Bus Terminal Block Cover and Fix
    MOR017Plug-in Terminal Block male, Horizontal Output, for Bus Power
    MOR022Plug-in Terminal Block female, Horizontal Output, for Bus Power