D1062S G.M. International s.r.l.
GM International

D1062S
Vibration Transducer Interface DIN-Rail Model D1062S

The single channel DIN Rail Vibration Transducer Interface D1062S provides a fully floating dc supply for energizing vibration transducers, accelerometers or 2-3 wires sensors located in Hazardous Area, and repeats the sensor input voltage in a totally isolated circuit located in Safe Area to drive vibration monitors or analyzers for rotating machinery control and supervision purposes.

FEATURES

  • Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2.
  • 0 to –20 V Input/Output Signal
  • Wide band signal transfer.
  • Input and Output short circuit proof.
  • High Accuracy.
  • Three port isolation, Input/Output/Supply.
  • EMC Compatibility to EN61000-6-2, EN61000-6-4.
  • 250 Vrms (Um) max. voltage allowed to the Instruments associated with the barrier.

STATUS

 
   PHASE-OUT
Next: SPARE-ONLY (2027-01-01)

Product lifecycle policy (EN)

ALTERNATIVE PRODUCT

CHANNELS

1

Request a free and personalized quotation!

Technical Data


Supply

Voltage 24 Vdc nom (20 to 30 Vdc). Reverse polarity protected, ripple within voltage limits ≤ 5 Vpp.
Current Consumption 60 mA with 20 mA transducer consumption and 2 mA output load, typical.
Power Dissipation 1.1 W with 24 V supply voltage, 20 mA transducer consumption and 2 mA output load typical.
Max. power consumption at 30 V supply voltage and short circuit condition, 1.9 W.

Input

Type 0 V to -20 V (10 KΩ impedance at terminals 15-16).
3 wires sensor supply voltage more than -21.0 V at 0 mA supply, more than -15.0 V at 20 mA supply (current limited at ≈ 25 mA) at terminals 14-16.
2 wires sensor supply voltage more than -15.0 V with constant current supply mode at terminals 15-16. Supply current selectable at 4 mA, 6 mA or 10 mA (current supply mode enabled connecting terminals 13-14, 4 mA with terminal 10 not connected, 6 mA connecting terminals 10-11 or 10 mA connecting terminals 10-12).

Output

Type 0 to -20 V on 10 KΩ load, with 10 Ω output resistance.
Response time 10 µs (10 to 90 % step change).
Output ripple ≤ 20 mVrms on 0.5 to 20 KHz band.
Frequency response DC to 10 KHz within 0.1 dB, 10 KHz to 20 KHz within 3 dB.

Performance

Type Ref. Conditions 24 V supply, 10 KΩ load, 23 ± 1 °C ambient temperature.
Calibration accuracy ≤ ± 0.05 % of full scale.
Linearity error ≤ ± 0.05 % of full scale.
Supply voltage influence ≤ ± 0.005 % of full scale for a min to max supply change.
Temperature influence ≤ ± 0.005 % on zero and span for a 1 °C change.

Isolation

Test Voltage I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; Out/Supply 500 V.

Environmental conditions

Operating temperature limits -20 to + 60 °C, relative humidity max 90 % non condensing, up to 35 °C.
Storage temperature limits – 45 to + 80 °C.

Safety description

Safety parameters Uo/Voc = 25.9 V, Io/Isc = 90 mA, Po/Po = 576 mW at terminals 14-16. Uo/Voc = 1.1 V, Io/Isc = 12 µA, Po/Po = 4 µW at terminals 15-16; Ui/Vmax = 30 V, Ci = 0 nF, Li = 1.5 µH at terminals 15-16 (when used with 3 wires transducer or 2 wires AC sensor connecting terminals 9-14). Uo/Voc = 27 V, Io/Isc = 90 mA, Po/Po = 576 mW at terminals 15-16 (when used with 2 wire constant current supply mode connecting terminals 13-14). Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C.

Mounting

Type EN/IEC60715 TH 35 DIN-Rail.
Weight about 150 g.
Connection by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2.
Location Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation.
Protection class IP 20.
Dimensions Width 22.5 mm, Depth 99 mm, Height 114.5 mm.

Data Sheet


Datasheet of D1062 ( EN )
D1000 Series Common Specifications and Dimensional Drawing ( EN )

Instruction Manual


Instruction Manual D1062 ( EN )
Instruction Manual D1000 Series ( EN | RU )
Ex safety instruction manual for D1000 series ( EN | IT )
INMETRO safety instruction manual for D1000 series ( PT )

Certifications


Type Description Area Number Issued by Issue Date
ATEX DEKRA ATEX D1000 Series English Certificate ( EN ) Europe DMT 01 ATEX E 042 X DEKRA 2022-04-25
ATEX IMQ Zone 2 Applications D1000 Series Certificate ( EN ) Europe IMQ 09 ATEX 013 X IMQ 2022-05-03
EMC D1000 EAC EMC Declaration of Conformity ( RU ) Eurasian Community ЕАЭС N RU Д-IT.НХ37.В.06311/20 EUROCERT 2020-08-13
Ex EAC Ex Certificate for D1000 Series ( RU ) Eurasian Community ЕАЭС RU С-IT.НА67.В.00113/20 TECHNOPROGRESS 2020-09-04
Ex FM No.3024643-3029921C Certificate ( EN ) North America 3024643-3029921C FM 2005-12-16
Ex INMETRO Certificate DNV 13.0108 X for D1000 series ( EN ) Brazil DNV 13.0108 X DNV 2022-12-10
IECEx IMQ IECEx Zone 2 Applications D1000 Series Certificate ( EN ) International IECEx IMQ 13.0011X IMQ 2022-05-03
IECEx DEKRA IECEx for D1000 Series ( EN ) International IECEx BVS 07.0027X DEKRA 2022-05-30
Maritime KR Maritime Certificate D1000 Series ( EN ) International MIL20769-EL001 KR 2022-07-04
Metrological Metrological Certificate Russia for D1000 Series ( RU ) Russia 64283-11 ROSSTANDART 2021-03-10

Declarations of Conformity


EU Declaration of Conformity D1000 series ( EN | IT )
EU Declaration of Conformity for D1000 series (zone 2) ( EN | IT )
EU Declaration of Conformity for RoHS, ASBESTOS. ( EN )
Declaration of G3 compliance for D1000_PSD1000-PSD1001-PSD1001C-PSD1004-PSD1220-PSD1220-098 SERIES ( EN )

Dimensions


Image of D1062S_size

Connections


Drawings


2d_drawing_D1000_dwg ( EN )
3d_drawing_D1000_dwg ( EN )
3d_drawing_D1000_stp ( EN )