D1060S

1 Ch, Frequency-Pulse Converter, Repeater and Trip Amplifier

Description

The single channel DIN-Rail Frequency-Pulse Converter, Repeater and Trip Amplifiers D1060S converts and repeats a low level frequency signal from magnetic pick-up, contact, proximity, open-collector transistor sensor, TTL CMOS located in Hazardous Area, into a 0/4-20 mA or 0/1-5 V or 0/2-10 V signal to drive a Safe Area load. Repeater output can be direct, divided by 10, 100, 1000, 10000, 100000, 1000000 or programmed with alarm function. One independent Alarm Trip Amplifier is also provided. Alarm energizes, or de-energizes, an SPST optocoupled open-collector transistor for high, low or low-startup alarm functions. The alarm trip point is settable over the entire input signal range. When repeater output is used as alarm output the unit provides two independent alarms.

Features

• Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2.
• Magnetic pick-up, proximity input sensor.
• Frequency range DC to 50 KHz input.
• Repeater output direct or divided by 10, 100, 1000, 10000, 10000 or 1000000.
• 0/4-20 mA, 0/1-5 V, 0/2-10 V Output Signal linear or reverse.
• High Accuracy, μP controlled converter.
• Three port isolation, Input/Output/Supply.
• EMC Compatibility to EN61000-6-2, EN61000-6-4.
• Fully programmable operating parameters.
• High Reliability, SMD components.
• High Density, 1 channel converter, repeater and trip amplifier per unit.
• Simplified installation using standard DIN Rail and plug-in terminal blocks.
• 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.

Supply

12-24 Vdc nom (10 to 30 Vdc)

Channels

1
D1060S - Frequency-Pulse Converter, Repeater and Trip Amplifiers

request a quotation

Download

    DTS0162 D1060S data sheet (English) (PDF 394 KB)
    ISM0054D1060S instruction manual (PDF 525 KB)
    ISM0062Manual Configuration Table (PDF 76 KB)
    ISM0102General D1000 Series Instruction Manual (PDF 2.39 MB)
    ISM0140UL Control Drawing for D1060S (PDF 142 KB)
    ISM0155General D1000 Series Safety Instruction Manual (PDF 3.35 MB)
    CRT003ATEX certificate n. DMT 01 ATEX E 042 X (I.S.) (PDF 9.52 MB)
    CRT005UL & C-UL barriers listing [link E222308] (PDF 227 KB)
    CRT014Metrological Certificate for D1000 Series (Russia) (PDF 779 KB)
    CRT020FM 3024643 (USA) & FM-C 3029921C (Canada) (PDF 3.42 MB)
    CRT028Korean Register Type Approval Certificate (PDF 577 KB)
    CRT032IECEx CoC for D1000 Series (I.S.) [link IECEx BVS 07.0027X] (PDF 2.80 MB)
    CRT047ATEX certificate n. IMQ 09 ATEX 013 X (non-sparking) (PDF 160 KB)
    CRT125IECEx CoC for D1000 Series (non-sparking) [link IECEx IMQ 13.0011X] (PDF 60 KB)
    CRT179DNV Maritime Type Approval Certificate (D1000 Series) (PDF 2.06 MB)
    CRT192TRCU Certificate for D1000 Series (PDF 3.15 MB)
    CRT216Ukraine certificate for D1000 series (PDF 3.50 MB)
    APN0005D1052-53, D1072-73 Signal Converter DIN Rail (PDF 25 KB)
    APN0007Universal AC Power Supply for Series D1000 (PDF 44 KB)
    SWC1090D1000 and E1000 Software Configurator for Windows
    BUSPower Bus Optional Enclosure
    MCHP065Din Rail Anchor, for Terminal Block Side of Bus Power
    MOR016DIN Rail End Stopper Terminal Block
    MOR017Plug-in Terminal Block male, Horizontal Output, for Bus Power
    MOR022Plug-in Terminal Block female, Horizontal Output, for Bus Power
    PPC1090Pocket Portable Configurator for D105* D106* D107*
    PPC1092D1000 Series Serial Adapter Configurator.
    USBADAPTRS-232 to USB Adapter.
Are you interested in this product? Request a quotation, search for an expert in your area or contact us.

« Previous: D1054S
D1060S
Next: D1061S »